6 INSTALLATION RS232, RS232 TTL, Light Pen or Laser Emulation 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink

Página 3 - ABLE OF CONTENTS

7INSTALLATION IBM 46xx or OCIA 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the MVC cable into the 10-pin socket on the

Página 4

8 INSTALLATION Keyboard Wedge 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on th

Página 5 - INTRODUCTION

9INSTALLATION Stand-Alone Keyboard 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socke

Página 6

10 INSTALLATION Low Speed USB (Integrated) 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the USB PowerLink cable into the 10-

Página 7

11INSTALLATION Notes for Laser Emulation IS3480-104 Only The IS3480-104 leaves the factory with the Laser Emulation Mode enabled. If the Rec

Página 8

12 SCANNER OPERATION Configurable Primary and Secondary Scan Pattern Modes There are two configurable scan pattern modes available with the IS34

Página 9

13SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON CLICK MODE WITH CODEGATE ENABLED For illustration purposes the un

Página 10 - INSTALLATION

14 SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON CLICK MODE WITH CODEGATE DISABLED For illustration purposes the

Página 11

15SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON HOLD MODE WITH CODEGATE ENABLED For illustration purposes the un

Página 12

Copyright © 2006 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced

Página 13

16 SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON HOLD MODE WITH CODEGATE DISABLED For illustration purposes the u

Página 14

17SCANNER OPERATION Sweet Spot Mode The sweet spot mode is used to determine where the maximum read rate area or “sweet spot” is located for a

Página 15

18 SCANNER OPERATION Audible Indicators When the IS3480 is in operation, it can provide audible feedback. These sounds indicate the status of the

Página 16 - SCANNER OPERATION

19SCANNER OPERATION Visual Indicators There are four LEDs located on the top of the IS3480. When the scanner is on, the flashing or constant il

Página 17

20 SCANNER OPERATION Failure Mode Indicators Flashing Blue and One Razzberry Tone This indicates that the scanner has experienced a laser subsy

Página 18

21SCANNER OPERATION Depth of Field Specifications* Normal Scan Zone Specifications are based on a 0.33 mm (13 mil) bar code. Figure 9. Norma

Página 19

22 SCANNER OPERATION Depth of Field Specifications* Reduced Scan Zone Specifications are based on a 0.33 mm (13 mil) bar code. Figure 10. Redu

Página 20

23SCANNER OPERATION Depth of Field by Bar Code Element Width* Normal Scan Zone MINIMUM BAR CODE ELEMENT WIDTH A B C D E F mm .13 .15 .19 .

Página 21

24 SCANNER OPERATION Depth of Field by Bar Code Element Width* Reduced Scan Zone MINIMUM BAR CODE ELEMENT WIDTH A B C D E F mm .13 .15 .19

Página 22

25SCANNER OPERATION IR Activation Range* QuantumE’s default power save mode† is Laser OFF. This power save mode turns the laser off after a con

Página 23

ii TABLE OF CONTENTS Introduction Product Overview ... 1

Página 24

26 TROUBLESHOOTING GUIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-METRO or 1-800-436-3

Página 25

27TROUBLESHOOTING GUIDE Symptoms Possible Cause(s) Solution All Interfaces The unit scans a bar code, but locks up after the first scan (the whi

Página 26

28 TROUBLESHOOTING GUIDE Symptoms Possible Cause(s) Solution All Interfaces During power up the unit beeps 3 times. There is a non-volatile RAM f

Página 27

29TROUBLESHOOTING GUIDE Symptoms Possible Cause(s) Solution RS232 Only The host is receiving data but the data does not look correct. The scanne

Página 28

30 DESIGN SPECIFICATIONS IS3480 Operational Light Source: Visible Laser Diode (VLD) @ 650 nm Laser Power: 1.1 mW Normal Depth of Field: 25 m

Página 29

31DESIGN SPECIFICATIONS IS3480 Electrical Voltage Supply: 5VDC ± 0.25V Operating Power: 1.375 W Standby Power: 1.0 W Operating Current: 275

Página 30 - TROUBLESHOOTING GUIDE

32 APPLICATIONS AND PROTOCOLS The model number on each scanner includes the scanner number and factory default communications protocol. SCANNER V

Página 31

33DEFAULT SETTINGS - COMMUNICATION PARAMETERS Many functions of the scanner can be "configured" - that is enabled or disabled. The sca

Página 32

34 DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER DEFAULT OCIA USB RS232* OR RS232 TTL LIGHT PEN IBM 46XXKBWLASER EMULATIONExpanded ID “]

Página 33

35DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER DEFAULT OCIA USB RS232* OR RS232 TTL LIGHT PEN IBM 46XXKBWLASER EMULATIONTransmit UPC-A

Página 34 - DESIGN SPECIFICATIONS

iii TABLE OF CONTENTS Depth of Field Specifications Normal Scan Zone ...

Página 35

36 DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER DEFAULT OCIA USB RS232* OR RS232 TTL LIGHT PEN IBM 46XXKBWLASER EMULATIONNixdorf ID 

Página 36 - APPLICATIONS AND PROTOCOLS

37DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER DEFAULT OCIA USB RS232* OR RS232 TTL LIGHT PEN IBM 46XXKBWLASER EMULATIONSupplements ar

Página 37

38 UPGRADING THE FLASH ROM FIRMWARE The MetroSet2 program is a functional component of Metrologic’s new line of Flash- based scanners. This progra

Página 38

39SCANNER AND CABLE TERMINATIONS Scanner Pinout Connections The IS3480 scanner interfaces terminate to a 10-pin modular socket. The serial # lab

Página 39

40 SCANNER AND CABLE TERMINATIONS IS3480-9 OCIA Pin Function 1 Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 RDATA 5 RDATA Return 6 C

Página 40

41SCANNER AND CABLE TERMINATIONS Cable Connector Configurations (Host End) “Standard” PowerLink Cable 53-53000x-3 coiled or 54-54000x-3 straight

Página 41

42 SCANNER AND CABLE TERMINATIONS Cable Connector Configurations (Host End) Keyboard Wedge PowerLink Cable 54-54002x-3 Pin Function 1 Keyboard Cl

Página 42 - MLPN 54-54014) are required

43LASER AND PRODUCT SAFETY Caution Use of controls or adjustments or performance of procedures other than those specified herein may result in haz

Página 43 - Scanner Pinout Connections

44 LASER AND PRODUCT SAFETY Notices This equipment has been tested and found to comply with limits for a Class A digital device, pursuant to part

Página 44 - Figure 16

45LIMITED WARRANTY The IS3480 QuantumE™ scanners are manufactured by Metrologic at its Blackwood, New Jersey, U.S.A. facility. The IS3480 Quantu

Página 45

1INTRODUCTION QuantumE™ is a miniature, omni-directional scanning engine with optional single-line scanning capability. The self-contained devic

Página 46

46 PATENTS Patent Information This METROLOGIC product may be covered by one or more of the following U.S. Patents: U.S. Patent No.; 5,216,232; 5

Página 47 - LASER AND PRODUCT SAFETY

47INDEX A AC ...2, 8–13 Accessories ...2, 3 Adapter...

Página 48

48 INDEX MetroSet2...44 Mode of Operation Button ...20 Primary ...

Página 52

March 2006, Web Version 01 Printed in the USA 00-02026E

Página 53

2 INTRODUCTION Scanner and Accessories BASIC KIT COMPONENTS Part No. Description IS3480 QuantumE™ Scanner 00-02026 IS3480 Installation and User’

Página 54

3INTRODUCTION Scanner and Accessories OPTIONAL ACCESSORIES Part No. Description 54-54002x-3 Keyboard Wedge PowerLink cable 54-54020x-3 Stand

Página 55

4 INTRODUCTION Scanner Components Figure 1a. Scanner Components ITEM NO. DESCRIPTION 1 Utility Connector Located Under Rubber Seal The rubber

Página 56 - Printed in the USA

5INTRODUCTION Caution and Serial Number Labels Figure 2. Mounting Specifications Figure 3. Maintenance Smudges and dirt can interfere

Comentários a estes Manuais

Sem comentários